####################################################### # # Innovus Command Logging File # Created on Sun Oct 18 17:23:49 2026 # ####################################################### #@(#)CDS: Innovus v25.11-s102_1 (64bit) 08/27/2025 13:03 (Linux 4.18.0-305.el8.x86_64) #@(#)CDS: NanoRoute 25.11-s102_1 NR250730-0928/25_11-UB (database version 18.20.674) {superthreading v2.20} #@(#)CDS: AAE 25.11-s028 (64bit) 08/27/2025 (Linux 4.18.0-305.el8.x86_64) #@(#)CDS: CTE 25.11-s034_1 () Aug 18 2025 08:55:47 ( ) #@(#)CDS: SYNTECH 25.11-s013_1 () Jul 30 2025 05:18:51 ( ) #@(#)CDS: CPE v25.11-s029 #@(#)CDS: IQuantus/TQuantus 24.1.0-s290 (64bit) Sun Jul 20 21:40:56 PDT 2025 (Linux 4.18.0-305.el8.x86_64) set_global _enable_mmmc_by_default_flow $CTE::mmmc_default suppressMessage ENCEXT-2799 getVersion redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_init_apr.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_init_apr.tcl} checkTimingLibrary all_setup_analysis_views all_hold_analysis_views getGenerateViaMode -auto -quiet report_message -end_cmd setAnalysisMode -analysisType onChipVariation redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_floorplan.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_floorplan.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_place_std_cells.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_place_std_cells.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_place_ties.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_place_ties.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_pre_cts_opt.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_pre_cts_opt.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_cts.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_cts.tcl} set_ccopt_property target_max_trans 150ps set_ccopt_property target_skew 150ps set_ccopt_property buffer_cells {CLKBUFX2 CLKBUFX4 CLKBUFX8} set_ccopt_property inverter_cells {CLKINVX1 CLKINVX2 CLKINVX4 CLKINVX8} set_ccopt_property clock_gating_cells ICGX1 check_design -type timing -out_file /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/RPT/CTS/chip_top.check_design.timing check_design -type cts -out_file /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/RPT/CTS/chip_top.check_design.cts check_design -type opt -out_file /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/RPT/CTS/chip_top.check_design.opt create_ccopt_clock_tree_spec clock_opt_design -cts -outDir /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/RPT/CTS/ redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_post_cts_opt.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_post_cts_opt.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_route.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_route.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_fill.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_fill.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_physical_verify.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_physical_verify.tcl} redirect -tee /nethome/dbenzi3/physical-design-onboarding-F26/outputs/apr/LOG/step_extract.log {source /nethome/dbenzi3/physical-design-onboarding-F26/scripts/apr/steps/step_extract.tcl}