3.5 KiB
Using Cadence Innovus
This document contains the following guides:
- Launching the Innovus GUI
- Viewing a design in Innovus
- Finding Innovus Commands
Launching the Innovus GUI
To launch the Innovus GUI:
-
SSH into the Linux server.
Important: Since you are launching a GUI, you must be using a remote terminal emulator with X11 forwarding, like FastX or MobaXterm.
-
cdinto a design directory. For the onboarding project, you'll want tocdintoPhysical-Design-Onboarding-Project/RTL2GDS/design/. -
Enter the C shell by running
tcsh. -
Run
source envsetupto set up the environment variables necessary to use Cadence tools. -
Run
innovus -legacy_uito launch the Innovus GUI.
Note: There are two versions of Innovus — the legacy version, and Stylus. Most industry flows use the legacy version, and so do we. This is why we pass the flag
-legacy_uiwhen we launch Innovus (the same flag the flow uses inscripts/SJapr). This distinction is important, since the CLI commands for the legacy and Stylus versions are different.
Viewing a Design in Innovus
Important: Before you open a design, you need to run the flow. The flow generates the output files required to open your design in Innovus.
The design files are stored in the
dbs/directory after the flow is run.
There are three ways to open a design in Innovus:
- With the command line
- As a launch flag
- With the GUI
To open a design with the command line:
-
In the terminal where you ran
innovus -legacy_ui, run the following command:
restoreDesign <path-to-db-folder>/<design-step-output>.enc.dat <top-module-name>
Where <design-step-output>.enc.dat is the directory written by saveDesign, and <top-module-name> is the name of your top-level design.
For example:
innovus 1> pwd
/nethome/user/Physical-Design-Onboarding-Project/RTL2GDS/design
innovus 2> restoreDesign dbs/postroute.enc.dat <top-module-name>
This will open the design output by the postroute step of the flow.
We can also view the design at other stages of the flow, with, for example, floorplan.enc.dat.
To open a design as a launch parameter:
We can open Innovus with a design preloaded. To do this, launch the Innovus GUI, but instead of using innovus -legacy_ui, use innovus -legacy_ui -init <path-to-db-folder>/<design-step-output>.enc.
Where <design-step-output>.enc is the restore script written by saveDesign alongside the .enc.dat directory.
For example:
user@rschsrv> pwd
/nethome/user/Physical-Design-Onboarding-Project/RTL2GDS/design
user@rschsrv> innovus -legacy_ui -init dbs/postroute.enc
This will open the design output by the postroute step of the flow.
We can also view the design at other stages of the flow, with, for example, floorplan.enc.dat.
To open a design with the GUI:
Don't open a design with the GUI. Be Based and use the CLI
Finding Innovus Commands
Innovus has ~1500 possible commands.
You can find commands and their associated documentation by searching relevant keywords on the Cadence Support website or by Launching Innovus, then running help *keyword* on the Innovus command line. (This is the fastest way to find relevant commands.)
For example, running help *macro* will output all the manual entries containing the term 'macro'.